招标/调研公告

2018LY0406多普勒胎心仪

发布日期:2018-11-30

<div><div id="fontzoom"> <p> </p><table align="left" border="1" cellpadding="0" cellspacing="0" width="763"><tbody><tr><td valign="top" width="102"><p><span>招标编号:</span></p></td><td valign="top" width="661"><p><span lang="EN-US">2018LY0406</span></p></td></tr><tr><td valign="top" width="102"><p><span>中文名称:</span></p></td><td valign="top" width="661"><p align="left"><span>多普勒胎心仪</span></p></td></tr><tr><td valign="top" width="102"><p><span>英文名称:</span></p></td><td valign="top" width="661"> </td></tr><tr><td valign="top" width="102"><p><span>数量:</span></p></td><td valign="top" width="661"><p align="left"><span lang="EN-US">2</span><span>台</span></p></td></tr><tr><td valign="top" width="102"> </td><td valign="top" width="661"><p><span lang="EN-US">1</span><span>、该机采用超声波频率为<span lang="EN-US">2.5MHZ,</span>超声波输出功率<span lang="EN-US">10mw/c</span></span><span>㎡</span><span>以下<span lang="EN-US">,</span>低频率、高灵敏度的效果,从胎心博动形成之初<span lang="EN-US">(</span>约在怀孕<span lang="EN-US">11</span>周以上<span lang="EN-US">)</span>开始测就能清晰听到胎心音,并瞬时显示胎心率,而且没有损伤。避免了用大功率来测早期胎心影响婴儿健康。</span></p><p><span lang="EN-US">2</span><span>、便携式、移动方便、操作简单、故障率低、大屏幕显示。</span></p><p><span lang="EN-US">*3</span><span>、探头托架可拆卸,便于清洁,防止感染,达到医院感控管理要求 。</span></p><p><span lang="EN-US">4</span><span>、 防水型探头可清洁和简单消毒,防止皮肤交叉感染,安全可靠。</span></p><p><span lang="EN-US">*5</span><span>、具有特殊的消除噪音功能,自动消除涂耦合剂产生的噪音,高保真扬声器发出优质清晰多普勒原音。</span></p><p><span lang="EN-US">6</span><span>、自动节电,低电压报警,专为本设备自主设计的充电技术,避免了外购充电器充电不稳定和不协调的充电效果,电池过充过放安全保护功能,延长电池的使用寿命,低功耗设计,充一次电常规使用可达7天。</span></p><p><span lang="EN-US">7</span><span>、外形专利技术,人性化的流线型外观设计,美观实用。</span></p><p><span lang="EN-US">8</span><span>、当胎儿心率超出上下限时,具有自动显示报警功能。</span></p><p><span lang="EN-US">9</span><span>、医疗级别,采用优质品牌进口元器件,做工考究,注重细节和效果。</span></p><p><span lang="EN-US">10</span><span>、额定超声工作频率:<span lang="EN-US">2.5MHz </span>±<span lang="EN-US">1%</span>综合灵敏度距探头:<span lang="EN-US">200mm</span>处综合灵敏度≥<span lang="EN-US">90dB</span></span></p><p><span lang="EN-US">11</span><span>、峰值负声压(<span lang="EN-US">p_</span>):<<span lang="EN-US">1MPa</span></span></p><p><span lang="EN-US">12</span><span>、输出波束声强(<span lang="EN-US">Iob</span>):<<span lang="EN-US">20mW/</span></span><span>㎝</span><span lang="EN-US">2</span></p><p><span lang="EN-US">13</span><span>、空间峰值时间平均声强(<span lang="EN-US">Ispta</span>):<<span lang="EN-US">100mW/</span></span><span>㎝</span><span lang="EN-US">2</span></p><p><span lang="EN-US">14</span><span>、输出超声功率:<<span lang="EN-US">0.015W</span></span></p><p><span lang="EN-US">15</span><span>、超声换能器敏感元件的有效面积:<span lang="EN-US">1.1</span></span><span>㎝</span><span lang="EN-US">2</span><span>±<span lang="EN-US">20%</span></span></p><p><span lang="EN-US">16</span><span>、电源范围:<span lang="EN-US">AC 220V </span>±<span lang="EN-US">10%<span>  </span>50Hz </span>;镍氢充电式电池:<span lang="EN-US">DC 7.2V</span></span></p><p><span lang="EN-US">17</span><span>、输入功率:<span lang="EN-US">20VA</span></span></p><p><span lang="EN-US">18</span><span>、电池连续工作时间最大功率时:<span lang="EN-US">160min</span></span></p><p><span lang="EN-US">19</span><span>、防滴液:主机:<span lang="EN-US">IPX0<span>    </span></span>探头:<span lang="EN-US">IPX4</span></span></p><p><span lang="EN-US">20</span><span>、心率检测范围:<span lang="EN-US">50bpm~240bpm </span>,误差±<span lang="EN-US">1 bpm</span></span></p><p><span lang="EN-US">21</span><span>、音频输出功率:<span lang="EN-US">1.2W </span></span></p><p><span lang="EN-US">22</span><span>、扬声器直径Ф:<span lang="EN-US">120mm</span>。</span></p><p><span lang="EN-US">23</span><span>、外形专利,亮点:流线型外形设计,按人体工程学原理,达到简单,实用,美观。</span></p><p><span lang="EN-US">24</span><span>、获<span lang="EN-US">2013</span>年广州市政府创新基金项目,创新技术亮点:噪音控制技术,自动消除涂耦合剂和探头检测移动时产生大的噪音,该技术实用性强<span lang="EN-US">,</span>并成功申请实用型新专利:应用于多普勒胎儿心率仪消除噪音的新型电路。</span></p><p><span lang="EN-US">25</span><span>、欧盟<span lang="EN-US">CE</span>,<span lang="EN-US">ISO13485</span>质量体系认证,<span lang="EN-US">SFDA</span>医疗器械注册证。</span></p></td></tr><tr><td valign="top" width="102"><p><span>备注:</span></p></td><td valign="top" width="661"><p><span>请将公司三证合一证件、医疗器械经营许可证、进口产品报关单、产品授权书、产品医疗器械注册证、设备清单、报价和实价、产品特性、功能、彩页、其他医院成交记录(发票复印件或合同复印件)等相关资料密封后交设备科树老师(地址:院本部中山楼<span lang="EN-US">8</span>楼设备科办公室),并在封面上注明招标编号、公司名称、联系人及电话,并以<span lang="EN-US">Word</span>表形式做简单的产品介绍,发到邮箱:</span><span lang="EN-US"><a href="mailto:3201723468@qq.com,联系电话81332367.在医院完成此设备竞争性谈判流程1"><span>3201723468@qq.com</span><span lang="EN-US"><span lang="EN-US">,联系电话81332367.</span></span><span lang="EN-US"><span lang="EN-US">在医院完成此设备竞争性谈判流程1</span></span></a></span><span>周后,相关结果将公布在设备科公告栏处,敬请留意。</span><span lang="EN-US"><a href="http://jwz.syshospital.orghttp://jwz.syshospital.org/UploadFiles/yyglw/… lang="EN-US"><span lang="EN-US">特别备注:请供应商下载该《设备信息表》并按要求填好,盖公司<span lang="EN-US">公章,一并投标资料提交。</span></span></span></strong></a></span></p></td></tr><tr><td valign="top" width="102"><p><span>备注<span lang="EN-US">2</span>:</span></p></td><td valign="top" width="661"> </td></tr><tr><td valign="top" width="102"><p><span>截止日期:</span></p></td><td style="width:496.1pt;border-top:none;border-left: none;border