招标/调研公告

2018LY0402营养注射泵

发布日期:2018-11-26

<div><div id="fontzoom"> <p> </p><table align="left" border="1" cellpadding="0" cellspacing="0" width="744"><tbody><tr><td valign="top" width="102"><p><span>招标编号:</span></p></td><td valign="top" width="643"><p><span lang="EN-US">2018LY0402</span></p></td></tr><tr><td valign="top" width="102"><p><span>中文名称:</span></p></td><td valign="top" width="643"><p align="left"><span>营养注射泵</span></p></td></tr><tr><td valign="top" width="102"><p><span>英文名称:</span></p></td><td valign="top" width="643"> </td></tr><tr><td valign="top" width="102"><p><span>数量:</span></p></td><td valign="top" width="643"><p align="left"><span lang="EN-US">1</span><span>台</span></p></td></tr><tr><td valign="top" width="102"> </td><td valign="top" width="643"><p><span>★</span><span>流速:<span lang="EN-US">1mL/h</span><span>~<span lang="EN-US">2000mL/h<span>         </span></span>可按<span lang="EN-US">1</span>、<span lang="EN-US">5</span>、<span lang="EN-US">10mL/h</span>递增或递减</span></span></p><p><span>误差:速度误差:±<span lang="EN-US">5%</span>(使用专用管路及营养液)</span></p><p><span>流量误差:±<span lang="EN-US">5%</span>(使用专用管路及营养液)</span></p><p><span>预置量:<span lang="EN-US">1ml~9999ml</span>,以<span lang="EN-US">1</span>、<span lang="EN-US">5</span>、<span lang="EN-US">10ml</span><span>递增或递减</span></span></p><p><span>阻塞灵敏度:高、中、低三档可选择<span lang="EN-US">,</span>也可关闭。</span></p><p><span>根据测试的营养泵运行时实时压力值,确定压力报警值三档范围为: </span></p><p><span>高:<span lang="EN-US">70</span>~<span lang="EN-US">120 Kpa<span>   </span></span>中:<span lang="EN-US">40</span>~<span lang="EN-US">90 Kpa<span>   </span></span>低:<span lang="EN-US">20</span>~<span lang="EN-US">60Kpa</span></span></p><p><span>报警功能:“气泡”、“阻塞”、“完成”、“开门”、“欠压”、“电池耗尽”、“操作遗忘”、“速度异常”“通讯异常”“超温”报警,且根据不同报警级别按照优先等级报警。</span></p><p><span>气泡:开、关</span></p><p><span>★</span><span>快排速度:<span lang="EN-US">600mL/h</span>~<span lang="EN-US">2000mL/h</span></span></p><p><span>★</span><span>反抽冲洗:有</span></p><p><span>★</span><span>加热温度:</span><span>范围:<span lang="EN-US">30</span>℃</span><span>~<span lang="EN-US">37</span>℃</span></p><p><span>精度:</span><span lang="EN-US">±5</span><span>℃</span><span>(室温,流速 <span lang="EN-US">≤ 200mL/h</span>)</span></p><p><span>配备硅胶条加温器</span></p><p><span>连续工作:连续工作时间不小于<span lang="EN-US">24</span>小时</span></p><p><span>★</span><span>内置电池工作时间:充电大于<span lang="EN-US">8</span>小时,以<span lang="EN-US">100mL/h</span>速度运行<span lang="EN-US">6</span>小时以上欠压,欠压半小时后耗尽</span></p><p><span>功耗:不大于<span lang="EN-US">20VA</span></span></p><p><span>外形尺寸<span lang="EN-US">(mm)</span>:<span lang="EN-US">150(</span><span>长<span lang="EN-US">)×120(</span>宽<span lang="EN-US">)×60(</span>高<span lang="EN-US">) </span>不含底座及突出部分</span></span></p><p><span>重量(裸机):约<span lang="EN-US">1.05kg</span></span></p><p><span>安全分类:<span lang="EN-US">П</span><span>类和带内部电源以及具有应用部分的<span lang="EN-US">CF</span>型</span></span></p><p align="left"><span>防水等级:<span>主壳体:</span><span lang="EN-US">IPX5</span></span></p><p><span>底座:<span lang="EN-US">IPX3</span></span></p><p><span>工作环境:<span>环境温度:<span lang="EN-US">10</span>℃~<span lang="EN-US">30</span>℃;</span></span></p><p><span>相对湿度:<span lang="EN-US">30%</span>~<span lang="EN-US">75%</span>(无结露);</span></p><p><span>大气压力:<span lang="EN-US">860 hPa</span>~<span lang="EN-US">1060hPa</span>;</span></p><p><span>使用电源:交流输入:<span lang="EN-US">AC220V/50Hz<span>  </span></span>内部电池:<span lang="EN-US">DC12V</span></span></p><p><span>外接电源:<span lang="EN-US">DC12V</span>(可连接车载<span lang="EN-US">12V</span>电源)</span></p><p><span>营养泵应在无强冲击振动,水和其它流体不能侵入装置内部,周围无腐蚀性气体的环境中工作。</span></p><p><span>存储环境:包装好的营养泵贮存在相对湿度不超过<span lang="EN-US">93%</span>(无凝露),无腐蚀性气体通风良好的室内,且室内温度条件为:<span lang="EN-US">-20</span>℃~<span lang="EN-US">+45</span>℃。</span></p></td></tr><tr><td valign="top" width="102"><p><span>备注:</span></p></td><td valign="top" width="643"><p><span>请将公司三证合一证件、医疗器械经营许可证、进口产品报关单、产品授权书、产品医疗器械注册证、设备清单、报价和实价、产品特性、功能、彩页、其他医院成交记录(发票复印件或合同复印件)等相关资料密封后交设备科树老师(地址:院本部中山楼<span lang="EN-US">8</span>楼设备科办公室),并在封面上注明招标编号、公司名称、联系人及电话,并以<span lang="EN-US">Word</span>表形式做简单的产品介绍,发到邮箱:<span lang="EN-US"><a href="mailto:3201723468@qq.com,联系电话81332367.在医院完成此设备竞争性谈判流程1">3201723468@qq.com<span lang="EN-US"><span lang="EN-US">,联系电话81332367.</span></span><span lang="EN-US"><span lang="EN-US">在医院完成此设备竞争性谈判流程1</span></span></a></span>周后,相关结果将公布在设备科公告栏处,敬请留意。<span lang="EN-US"><a href="http://jwz.syshospital.orghttp://jwz.syshospital.org/UploadFiles/yyglw/… lang="EN-US"><span lang="EN-US">特别备注:请供应商下载该《设备信息表》并按要求填好,盖公司公章,一并投标资料提交。</span></span></strong></a></span></span></p></td></tr><tr><td valign="top" width="102"><p><span>备注<span lang="EN-US">2</span>:</span></p></td><td valign="top" width="643"> </td></tr><tr><td valign="top" width="102"><p><span>截止日期:</span></p></td><td valign="top" width="643"><p><span lang="EN-US">2018.12.02</span></p></td></tr></tbody></table><p><span lang="EN-US"> </span></p><p><span lang="EN-US"> </span></p><p><span lang="EN-US"> </span></p> </div></div>